How to calculate your heating area?
- Dwayne hibner

- 18h
- 2 min read

When choosing a woodstove, calculating the right heating area is paramount so you can target the right models for your space.
1. Calculate the theoretical heating area
If you only need to heat one floor, the heating area is the same as that floor's area. For instance, in a 30’ X 30’ single-story house, the heating area is 900 ft².
If you need to heat two floors, determine the total area of the lower floor (where the unit is placed) and add 50% of the upper floor's area. Therefore, if a unit is installed in the basement of a house with 900 ft² per floor, you will require a unit with a capacity of at least 1,350 ft² (900 + 450).
If more than two floors need heating, calculate the total area of the lower floor (where the appliance is placed), add 50% of the middle floor's area, and then add 25% of the upper floor's area. Thus, if a unit is installed in the basement with 900 ft² per floor, you will need a unit with a capacity of at least 1,575 ft² (900 + 450 + 225).
2. Calculate the real heating area
You must now adjust the theoretical area to heat by adding a comfort margin, based on the following elements, to obtain the real area to heat:
Insulation level of your home: the better a home is insulated, the more heat is kept inside. The number, type and orientation of doors and windows as well as the thermal resistance of the walls influence the insulation level of your home.
Air circulation: a space with a large number of divisions will be more difficult to heat because heat distribution is not optimal. Since heat goes up, spaces with high or cathedral ceilings are also more difficult to heat.
Type of use: an appliance used to heat your home almost continuously must be powerful enough to avoid overheating and premature wear. Conversely, a stove used to create atmosphere with occasional fires should not be too powerful in order to avoid making fires that are too small and generate more creosote.
Location: the further north you are, the harsher the winter and the more you will need a high-performance stove to achieve the same comfort. The same logic applies to places very exposed to the wind.
For example, for a theoretical heating area of 1,400 ft² with very favorable conditions (ambiance use, good insulation, good air circulation, etc.): it is recommended to slightly exceed the theoretical heating area and to aim for an actual heating or cooling area of 1,600 ft².
For the same theoretical heating area, but with less favorable conditions (sustained use, poorer insulation, poorer air circulation): it is recommended to add a greater margin of comfort and aim for an actual area of 1,800 ft², or even 2,000 ft².
.png)


Comments